Film width measurement controller
Inline measurement · PV / SV in millimetres · 测宽仪
A gauge and a controller on one faceplate: the fittings read the running web, the display shows measured width against set width in millimetres, and the trim valve is driven from the same box.
The unit measures the width of a running web of film and holds it to a set figure. Measured width and set width sit on one two-line display in millimetres, so the operator reads the deviation directly instead of converting a raw sensor count. The correction element — an air valve — is driven from the controller, which keeps the trim loop inside one device rather than splitting it across a gauge and a separate valve driver.
Published specification
| Parameter | Listed value |
|---|---|
| Supply | 380 V, three-phase |
| Display | Two-line, PV (measured) and SV (set) in millimetres |
| Sensor fittings | One or two, chosen with the order |
| Correction output | Air valve, driven from the controller |
| Warranty | 12 months |
| Certificate | CE |
Model code, price, minimum order and lead time are issued with the quotation — the listing for this line carries a code and a rated power that belong to another brand, so neither is printed here. Send the web widths you need to cover and the factory returns the matching sensor set with the quote.
What to send with the enquiry
The sensor set and the faceplate are the two things that cannot be guessed from a catalogue, so they are settled in the first reply rather than after an order. Five lines in the message is enough:
- The web width range you need to measure, and the tolerance that counts as off-width
- One or two sensor fittings — tell us the line layout and we will confirm which
- Quantity for the first order and the annual figure behind it
- Faceplate artwork, brand name and carton marking if the unit carries your label
- The supply and control voltage at the point of installation

On the unit
Six buttons, one number that moves.
The faceplate is the same family of interface used on the process controllers: program, enter, reset, manual/auto and two arrows, with the measured width and the set width on the two display lines above them. Underneath, the glands leave the base plate in a row, which is what lets one box carry both the sensor fittings and the valve cable.

Faceplate and display
PRG, ENT, reset, manual/auto and two arrows. The two display lines carry measured width and set width, and M/A takes the trim loop out of automatic so the operator can correct it from the keys.

Base plate and gland entries
Cable entries in a row along the base plate, so sensor leads and the valve cable land in the same place instead of being split across two boxes on the wall.
Same measurement loop. Your name on the faceplate.
The line is built on the same floor and the same test bench as the drives, so private label is a programme rather than a special order: your artwork on the faceplate, your parameter set loaded before the carton is sealed, your marking on the carton. The measurement itself — trimming the web to a set width — is what the unit does whoever sells it.