Manufacturing plant · Jiangmen, CN
English · GlobalRequest a quoteStore

G600

Modular High-Performance Vector Drive

Compact modular AC drive with RS-485 Modbus, ratings 0.75 kW to 800 kW.

Upgraded modular vector platform. G600 features an ultra-reliable compact integrated power module, dual-keypad interface, integrated RS-485 Modbus communication, and high cost-effectiveness across general industrial machinery, compressors, and pump sets.

Compact structure with small integrated module for tight cabinet baysDual parameter display with detachable digital operator panelRS-485 Modbus communication protocol embedded as standardIntegrated solar pumping MPPT firmware option available on requestBoost module option for sites where the input voltage sags under loadGPRS module option for remote pump and panel telemetry without a PLCCabinet build to IP54 for dusty or washdown plant rooms

Electrical envelope

Download this sheet as PDF

ParameterListed value
Rated power0.75–800 kW
Nominal voltage220 V / 380 V
Control modesSensorless Vector (SVC), V/F control
Starting torque0.5 Hz / 150% (SVC)
CommunicationRS-485 Modbus RTU standard, one host to several drives
MPPT controlAdvanced MPPT, optional solar pump firmware
ProtectionOvercurrent, overvoltage, undervoltage, motor overload, phase loss
Operating temp−10 °C to +50 °C
InstallationWall mount, slide-in or cabinet mount
Typical applicationsIndustrial automation · Pump control · Fan control · Conveying systems · Textile machinery · Paper and printing · Mining and metallurgy · Electric vehicle · Food and beverage processing
Warranty12 months factory warranty
MOQ1 piece

Frames and packages

ModelRatedDimensionsPackage
G600-4T0.75G0.75 kWCompact modular frame ACartonRequest
G600-4T7.5G7.5 kWCompact modular frame BCartonRequest
G600-4T37G37 kWCompact modular frame CCartonRequest
G600-4T160G160 kWFloor-standing frame DCrateRequest

Model codes and frame variants beyond this table are quoted to order. Final specification confirmed at quotation.

Where this platform is used

The frame is chosen from the load profile rather than from the nameplate. Each page below states the selection rule, the parameter that matters, and where the platform stops.

Which platform fits your duty

Six platforms overlap on paper. They do not overlap on the plant floor. The table below is the same routing the sales desk uses when a specification arrives without a model code — read your duty, then take the row that matches.

PlatformTypical dutyPick it whenLook elsewhere when
G5000.75–800 kWCrushers, conveyors, mixers, hoists and grid conditions that sag or spikeStarting torque is the constraint, or the grid is above 380 VThe build only needs a compact modular drive on 380 V with Modbus
G6000.75–800 kWPanel-builder cabinets, multi-drive line control, RS-485 Modbus networksThe panel is built in-house and the drive must sit on a Modbus RTU busThe site is above 380 V, or the load needs the G500 overload envelope
G580 / G580M4–37 kWDeep-well and surface pumping, solar pump arrays, pump and fan retrofitThe duty is a pump or fan, or the site runs on PV with a variable DC windowThe load is a crusher, hoist or extruder with heavy starting torque
G1000.4–4 kWSmall pumps, fans, conveyors and single-machine retrofits inside a panelThe motor is 4 kW or below and the panel has limited depthThree-phase 380 V duty above 4 kW, or anything needing a cabinet build
AC Servo Driver & Motor0.4–7.5 kWPositioning axes, indexing tables, packaging and CNC feed motionThe axis needs position or torque control, not just variable speedThe duty is a pump or fan where a V/F drive already does the job
A6-CUniversal inputTemperature and process loops — extrusion, ovens, dryers, heat treatThe signal to control is a process variable, not a motor shaftYou need to run a motor: this is a controller, not a drive

Do not have a model code yet? The pump and fan sizing calculator turns flow and head into a power band, then into one of these platforms.

Two duties on one line — a pump plus a conveyor, a solar array plus a grid-tied fan — usually mean two platforms in one cabinet, not one oversized drive. Send both duties in one enquiry and the two models are quoted together.

Questions that come before a purchase order

What power range does the G600 cover?

0.75–800 kW across 220 / 380 V, 3-φ in · 3-φ out. Frame and package variants outside the published table are quoted to the required duty.

Can the G600 be ordered in single units?

1 piece. Private-label and custom builds start at 100 pieces.

How is overload handled?

Overload is confirmed against the duty on quotation — send the load curve with the enquiry so the rating is set on the real duty, not the motor nameplate.

What certification comes with it?

CE LVD/EMC · ISO 9001. Contracts, invoices and the ISO 9001 certificate are issued by Goldbell Electric Drives and Controls (Shenzhen) Co., Ltd.; manufacturing runs at the 12,000 m² plant in Jiangmen.

What are the commercial terms?

Lead time 10 days, 1–5,000 pieces; 12 months factory warranty. Quotation is issued against your specification — no price is published on this site.

G600 Modular High-Performance Vector Drive
G600G600 modular vector drive · 0.75–800 kW
0.75–800 kWPower range
220 / 380 VVoltage
3-φ in · 3-φ outPhase
IP20 / Optional IP54 CabinetEnclosure
SVC · V/F · Advanced Vector · Optional MPPTControl
CE LVD/EMC · ISO 9001Certificate