Municipal & Surface Pumping

Drives for municipal and surface pumping.

Pressure loops, multi-pump staging and soft-start ramps on the G500 platform, from 0.75 kW to 710 kW, with the frame chosen on the pump curve rather than on the motor nameplate.

Surface pumping station with AC drives on a pressure loop
Surface pumping · pressure loop and stagingG500-G/P · 380 V

This duty at a glance

SeriesG500-G/P
Band0.75–710 kW
Overload150% / 60 s on the G rating
Voltage220 / 380 V

A frame number is only issued against the duty point: send the curve, the cycle or the belt data and the rating comes back confirmed, not estimated.

Platforms used for this duty

What this duty actually asks of the drive

A water network is a variable-torque load with a hard constraint: the pressure at the far end of the line has to stay inside a band that nobody at the pump house can see. The drive runs a PID loop on the pressure transmitter, and the ramp has to be slow enough that a valve opening downstream does not turn into a pressure spike.

On multi-pump stations the staging logic matters more than the single drive. Pumps are added on falling pressure and dropped on rising flow, with the running hours rotated so one pump does not take every start. This is a parameter and wiring exercise, and it is the part buyers usually want demonstrated before they order.

Wastewater adds the failure modes: ragging, dry-run and a wet well that fills faster than the pumps can clear it. The job of the drive is to trip before the pump is damaged and to restart without an operator being called out.

How the frame is chosen

Duty conditionFrame ruleWhat gets set
Centrifugal pump, clean waterP rating at motor kWPID on pressure transmitter, ramp set to line volume
Multi-pump stationP rating per pump, one drive per pumpStaging thresholds and running-hour rotation configured
Wastewater with a wet wellP rating, one frame up if the start is loadedDry-run protection and restart delay enabled
Long cable run to a submersibleFrame unchangedCarrier reduced to 4 kHz or below

Frame numbers are issued against the duty point, not against the motor nameplate. Send the load profile — curve, head, cycle or belt data — and the rating is confirmed on it.

Where this platform stops

A page that claims to cover every case is worth less than one that says where the catalogue ends. These are the limits that decide whether the answer is a standard frame, a cabinet build, or a different platform entirely.

Remote SCADA integration is quoted per protocol; RS-485 Modbus RTU is standard on G600 and the servo series, not on every G500 build.
IP20 is the standard protection on the G500; IP54 cabinet builds and floor-standing frames are to order.
No pump curve, no frame number — this site does not publish a rating without the duty point.

Questions that come before a purchase order

Can the drive run a PID pressure loop on its own, without a PLC?

Yes. The built-in PID function holds the pressure transmitter loop and the drive ramps to hold setpoint. For a multi-pump station, the staging logic is configured in the drive parameters and the pumps are interlocked — send the station layout with the enquiry and the configuration is returned with the quotation.

What overload does the G rating give me?

150% of rated current for 60 s on the G rating. Pumps are variable-torque loads, so the P rating at motor kW is normally enough; loaded starts or short ramps are the cases where one frame up is the cheaper decision.

Do you supply the pressure transmitter and the panel?

The site publishes drives, not panels. What is quoted is the drive, the parameter set for your loop and the wiring schedule; the transmitter, the panel and the enclosure beyond IP20 are specified by your integrator or quoted as a cabinet build on the G500 frames.

What is the lead time for a station of several drives?

Published lead time is 10 days for 1–5,000 pieces. A station order is quoted against the frame list and the parameter files, so the confirmation comes with the proforma rather than from this page.

Other duty profiles

Next step

Send the duty point. Get a frame number back.

Power, voltage, load type and the number of units is enough to quote. Anything short of that gets a question back the same working day.

≤ 3 h
Reply on a working day
1 pc
Minimum order
10 days
Lead time to dispatch