Six loads, one platform decision.

The drive is chosen from the load profile, not the motor nameplate. Below is the matching rule used on this site and the parameter that matters in each case.

Solar pump drive in service at an off-grid community water point
In service · off-grid solar pumping, community water pointG580MPV-G · 380 V
One drive platform across conveyor, pump, fan and HVAC duties

Conveyor · pump · fan · HVAC — one parameter platform, four duty profiles

How the match is made

Variable-torque loads — centrifugal pumps and fans — take a frame at motor rating because torque falls with the square of speed. Constant-torque loads — conveyors, spindles, compressors — need one frame up when the start is loaded or the ramp is short.

Variable torqueFrame at motor rating · V/F curve
Constant torqueOne frame up on loaded starts
Long cable runsCarrier reduced to 4 kHz or below
Unattended solarDry-run and low-voltage protection enabled