Order code reference
Six lines, six ways a code is built.
Four drive series, one servo pack and one temperature controller — and no two of them encode the same things. Only the G500 carries a load letter and a brake suffix. Only the G500 and the A6-C have a printed rule behind them at all; the servo pack carries a frame and a power and nothing else. This page puts all six side by side, says which of them is quoted and which is read off a model list, and decodes one real published code per line so an enquiry can be written without a second email.
What each line encodes
Four of the six rows below are marked derived. That is not a hedge — it means no field diagram is printed for that line, so the fields were read off the published model list. On a standard order the G600, G580 and G100 only have one supply grade and one load type in print, which is why their codes look shorter than a G500 code; any other supply grade is quoted against the nameplate voltage rather than stocked as a catalogue line. The servo pack goes further still and encodes a frame and a power and nothing else, so the empty cells in its row are the point of the row.
| Series | Range | Supply token | Load letter | Option fields | Field basis |
|---|---|---|---|---|---|
| G500 | 0.75–900 kW | S · 2T · 4T · 5T · 7T · CT | G / P | B optional | Printed rule |
| G600 | 0.75–900 kW | 4T | G only | Not shown | Derived |
| G580 / G580M | 0.4–900 kW | 4T | G only | Not shown | Derived |
| G100 | 0.4–4 kW | 2S | None | Not shown | Derived |
| AC Servo pack | 0.4–7.5 kW | Not in the code | None | Not in the code | Derived |
| A6-C | Universal input | S · D · T | None | OUT1–3 · AO · input signal · current display | Printed rule |
G500
Heavy-Duty Vector Drive · 0.75–900 kW
Printed rule — Catalogue p.05 prints the field diagram, so every field below is quoted — including the six voltage grades and the brake-unit suffix.
Taken from the catalogue code rule. The two fields buyers misread most often are the voltage grade and the load type — those two decide the frame and the overload curve.
- G500
- Inverter series
- Voltage grade
- S single-phase 220 V · 2T three-phase 220 V · 4T three-phase 380 V · 5T three-phase 480 V · 7T three-phase 690 V · CT three-phase 1140 V
- Motor power
- Rated motor power in kW, e.g. 0.7 = 0.75 kW
- Type
- G heavy-duty load · P light-duty load
- Braking unit
- B brake unit fitted · blank not fitted
Published example
G500-4T110G
| G500 | Inverter series |
| 4T | Three-phase 380 V supply |
| 110 | 110 kW rated motor power |
| G | Heavy-duty load rating |
| no B | No integrated braking unit |
The published pair G500-4T110G / 132P is the same frame: 110 kW heavy duty or 132 kW light duty. Pick the letter from the load, not from the motor nameplate alone.
G600
Modular High-Performance Vector Drive · 0.75–900 kW
Read from model list — No code diagram is printed for the G600 and no example codes are either. Fields are read off the published model list.
The catalogue prints a code-rule diagram for the G500 only. The G600 fields below are read off the published model list using the same scheme — every listed model is 4T with the G suffix, so on a standard order the power rating is the only field you choose. Any other voltage grade is quoted against the nameplate voltage, not stocked as a catalogue line.
- G600
- Inverter series
- Voltage grade
- 4T three-phase 380 V — the only grade in the published G600 model list. S single-phase 220 V and 2T three-phase 220 V follow the same field scheme; other grades quoted against the nameplate voltage
- Motor power
- Rated motor power in kW, read as printed. The published frames run 0.75, 7.5, 37 and 160 kW; the ladder continues to 900 kW on engineered frames, which are quoted per frame rather than listed here
- Type
- G heavy-duty load — every published G600 model carries the G suffix; no P-rated G600 appears in the list
Published example
G600-4T160G
| G600 | Inverter series |
| 4T | Three-phase 380 V supply |
| 160 | 160 kW rated motor power |
| G | Heavy-duty load rating |
| no B | No brake suffix on any published G600 model |
On a standard G600 order the power rating is the only field you choose — every published model is 4T with the G suffix.
G580 / G580M
Versatile Vector & Solar Pump Drive · 0.4–900 kW
Read from model list — No code diagram is printed for the G580. Fields are read off the published model list, including the M form on the front label.
No code-rule diagram is printed for this series; the fields below are read from the published model list. The M form is the one on the front label and on every listed model, so order a G580M unless the factory confirms otherwise. Voltage grade and power rating are the two fields that decide the frame.
- G580M
- Series as written on the front label and on every model in the published list; the series is also referred to as G580
- Voltage grade
- 4T three-phase 380 V — the only grade in the published model list. S single-phase 220 V and 2T three-phase 220 V follow the same field scheme; other grades quoted against the nameplate voltage
- Motor power
- Rated motor power in kW, read as printed. The published wall-mount frames run 4.0, 7.5, 15, 22 and 37 kW; the ladder continues to 900 kW on cabinet frames, which are quoted per frame rather than listed here
- Type
- G heavy-duty load — every published G580M model carries the G suffix; no P-rated G580 appears in the list
- M suffix
- Not defined anywhere in the catalogue. Treat it as part of the ordered model code, not as a separate option you select or omit
Published example
G580M-4T4.0G
| G580M | Series as printed on the front label |
| 4T | Three-phase 380 V supply |
| 4.0 | 4.0 kW rated motor power |
| G | Heavy-duty load rating |
| M | Part of the ordered code, not a catalogue option |
The M is not a separate option you add or drop: every published G580M model carries it. Order the M form unless the factory confirms otherwise.
G100
Compact Micro Drive · 0.4–4 kW
Read from model list — The G100 section prints no code diagram and no model codes at all, so this table rests entirely on the published model list.
This is the series with the thinnest paper trail: the catalogue prints no code-rule diagram for the G100 and no model codes either, so the fields below are read from the published model list. Two things the code does not tell you — the G100 carries no load-type letter, and single-phase to single-phase versus single-phase to three-phase output is not encoded in it. State the output on the enquiry; the same drive code is used for both.
- G100
- Inverter series
- Supply code
- 2S on every model in the published list — the series is single-phase 220 V input only. Printed as 2S, not as the G500 rule’s S token, so do not map the two mechanically
- Motor power
- Rated motor power in kW, read as printed: 0.4, 0.75, 1.5, 2.2, 4.0
- Load type
- No G or P letter on any published G100 model. The series is listed with V/F control only, so there is no heavy/light-duty choice to make in the code
- Output wiring
- Not in the code. 1-φ to 1-φ and 1-φ to 3-φ run off the same series, so specify which one the motor needs
Published example
G100-2S4.0
| G100 | Inverter series |
| 2S | Single-phase 220 V supply |
| 4.0 | 4.0 kW rated motor power |
| no letter | No load-type suffix on this series |
This code does not encode the output side. 1-φ to 1-φ and 1-φ to 3-φ run off the same model, so the output has to be stated on the enquiry.
AC Servo Driver & Motor
High-Precision Servo System · 0.4–7.5 kW
Read from model list — The catalogue gives the servo pack two feature pages and prints no field diagram and no code list, so this table is read off the four published pack codes.
No field diagram is printed for this line — the catalogue gives the servo pack two feature pages and no code rule and no code list, so the fields below are read off the four published pack codes, which carry a frame size and a kW figure and nothing else. Everything that decides whether the axis behaves sits outside the code: rated speed, rated torque, encoder class, holding brake, cable length and the driver supply grade. State those six on the enquiry and the factory matches the pack; leave them out and the quotation picks the default, which is where servo orders usually go wrong.
- GS
- Servo pack. Driver, motor and cables are quoted as one set under this prefix — the driver is not a separately published catalogue line
- 060 · 080 · 130
- Motor flange frame, written as the frame column of the published list. Frame sets the mounting footprint and how much inertia the motor brings to the machine, so it is chosen from the mechanics, not from the power
- 0.4KW · 0.75KW · 1.5KW · 3.8KW
- Rated motor power, as printed after the frame. It is the only rating the code fixes — not the peak, not the torque, not the speed
- Not in the code
- Rated speed (1000 / 1500 / 2000 / 3000 RPM), rated torque, encoder class (2500 PPR incremental, 17-bit or 23-bit absolute), holding brake, cable length, and 220 V versus 380 V driver supply. Two packs reading the same code can differ on all six
Published example
GS-060-0.4KW
| GS | Servo pack — driver, motor and cables ship as one set |
| 060 | Motor flange frame (060 / 080 / 130) |
| 0.4KW | 0.4 kW rated motor power |
| no further field | Rated speed, torque, encoder class, brake, cable length and supply grade are not encoded |
The four published packs carry a frame and a power and no other field, so two orders reading the same code can still differ on speed, encoder and brake. Those six items are what the quotation has to pin down before the motor is built.
A6-C
Intelligent PID Process Controller · Universal input
Printed rule — The A6 series guide prints an eleven-position diagram with a worked example, so every field below is quoted — including the two positions marked not supported.
The A6 series prints an eleven-position rule with a worked example, so every field below is quoted, not inferred. Positions ⑩ and ⑪ are marked not supported on this series: the A6 has no expansion slot and no custom-code option, which is where it parts company with the H6 — if you need RS485 or an extra input inside the code, that is the reason to move up a series rather than to ask for an A6 with that position filled. What the code still does not settle is the cut-out. The four printed outlines need 45 × 45, 45 × 91.5, 67 × 67 or 91 × 91 mm, and the 1/16-DIN panel form sold as A6-C here cuts 48 × 48 mm, matching none of them — so send the cut-out you are machining and let the factory return the matching letter.
- A6
- Controller series — dual-display, universal-input PID
- A · B · C · D
- Outline letter and the panel cut-out it needs: A 76 × 44 × 44 mm (45 × 45 mm) · B 68 × 44 × 90 mm (45 × 91.5 mm) · C 68 × 66 × 66 mm (67 × 67 mm) · D 68 × 90 × 90 mm (91 × 91 mm)
- OUT1 — 1 / 2 / 3
- First output: 1 relay · 2 SSR (solid state) · 3 analog
- OUT2 — 1 / 2 / 3
- Second output: 1 relay · 2 SSR · 3 custom
- OUT3 — 0 / 1 / 2 / 3
- Third output: 0 none · 1 relay · 2 SSR · 3 custom
- S · D · T
- Working voltage: S AC/DC 100–240 V · D DC 24 V · T AC/DC 300–440 V
- Current display — 0 / 1
- 0 none · 1 fitted, with a 100 A current transformer supplied from the factory. This is the position that adds current monitoring without another instrument
- AO output — 0 / 1
- 0 none · 1 fitted. Whether that analog output leaves as 0–10 V or as a current loop is set by the internal JP1 jumper, so it is not a second code digit
- T · A
- Input signal: T any temperature sensor · A analog, 4–20 mA or 0–10 V
- Expansion — ⑩
- Not supported on the A6. The H6 in the same family uses this position for RS485, an extra input, or both
- Custom code — ⑪
- Not supported on the A6
Published example
A6-B110S00T0-□
| A6 | Controller series |
| B | Outline 68 × 44 × 90 mm · 45 × 91.5 mm cut-out |
| 1 | OUT1 — relay output |
| 1 | OUT2 — relay output |
| 0 | OUT3 — none fitted |
| S | Working voltage AC/DC 100–240 V |
| 0 | No current display |
| 0 | No analog output |
| T | Input — any temperature sensor |
| 0 | Expansion — not supported on the A6 |
| □ | Custom code — not supported on the A6 |
This is the printed example, not a stocked item: the last two positions are dead on this series. The -R / -S / -I suffixes used on the A6-C listings here are output-type shorthand for a quotation — R is position ③ set to 1, S is ③ set to 2, I is ③ set to 3. On a purchase order the eleven positions are written out in full.
What to send with the code
A code alone fixes the hardware but not the duty. These five lines are what the sales desk needs to confirm a rating instead of guessing at it, and they are the same ones that come back as questions when they are missing.
- The model code you are replacing, or the load duty if there is no code yet
- Supply voltage and phase, read off the site nameplate rather than assumed
- Motor nameplate power, voltage and full-load current — on a servo pack, rated speed and torque as well
- The output the motor needs — especially on G100, where the code does not carry it
- On A6-C, the panel cut-out you are machining and the sensor type; on a servo pack, encoder class, brake and cable length